abnormal overvoltage

基本解釋異常過(guò)電壓,事故過(guò)電壓

網(wǎng)絡(luò)釋義

1)abnormal overvoltage,異常過(guò)電壓,事故過(guò)電壓2)abnormal overvoltage,異常過(guò)電壓;事故過(guò)電壓3)accident over-voltage,事故過(guò)電壓4)abnormal overvoltage,異常過(guò)電壓5)Fault over-voltage,故障過(guò)電壓6)overvoltage caused by fault,故障激發(fā)過(guò)電壓

用法和例句

The inside over-voltage mainly including the control over-voltage,resonance over-voltage and accident over-voltage probably occurs at any moment,and threatens the safe running of electric power system and the service life of electrical equipment;therefore,the precaution measures are required.

電力網(wǎng)過(guò)電壓分為外過(guò)電壓和內(nèi)過(guò)電壓,其中內(nèi)過(guò)電壓主要有操作過(guò)電壓和諧振過(guò)電壓及事故過(guò)電壓,內(nèi)過(guò)電壓隨時(shí)都會(huì)發(fā)生,時(shí)刻威脅著電力系統(tǒng)的安全運(yùn)行和電氣設(shè)備的壽命,需要有防范措施。

Research on Inner Overvoltage in UHVDC Transmission Line Caused by Flashover to Ground Fault

特高壓直流輸電線路故障過(guò)電壓的研究

The Analysis and Countermeasure to Over-Hot Failure for the Generator Encourage Extremity;

發(fā)電機(jī)勵(lì)側(cè)端部壓圈過(guò)熱故障的分析

Intermittent grounding faults and overvoltages due to arcing faults3 are eliminated.

可消除間歇性接地故障以及由電弧故障引起的過(guò)電壓:

Cause analysis and prevention of the sparking fault due to overheated electric brush in air compressor's motor

空壓機(jī)電機(jī)電刷過(guò)熱跳火故障原因分析及預(yù)防

Study on Fault Location of Transmission Line in High Voltage Power Network Based on Overvoltage On-line Monitoring System

基于過(guò)電壓在線監(jiān)測(cè)系統(tǒng)的高壓電網(wǎng)輸電線路故障定位研究

Research on General Diagnosis Techniques for Overheating Faults of Power Transformer;

電力變壓器過(guò)熱故障綜合診斷技術(shù)研究

Cause Analysis and Countermeasures of Frequency Converter Overvoltage Failure

變頻器產(chǎn)生過(guò)電壓故障的原因分析及對(duì)策

Describing of the Handling Process and Brief Analyzing of the Cause of Tripping about the Third Transformer Starting in the Second Substation

二降壓3號(hào)主變壓器啟動(dòng)送電后跳閘故障原因及處理過(guò)程淺析

The chiller is dexigned to be with current over-load protector, high voltage and low voltage construction and electric time-delay safeguard,When malfunction happende, it could alarm and show the cause of the problem in time.

有電流過(guò)載保護(hù),高低壓制及電子時(shí)間延遲安全裝置,當(dāng)發(fā)生故障隨即發(fā)出警號(hào)顯示故障原因。

However, in this system serious over voltage may occur due to arc grounding fault.

然而,在此系統(tǒng)中可能由于電弧接地故障而出現(xiàn)嚴(yán)重過(guò)電壓。

The Statistical Characteristics of Partial Discharges from Discharge Development to Insulation Breakdown in Discharge Fault Models of Power Transformers;

變壓器典型放電故障擊穿過(guò)程中局部放電的統(tǒng)計(jì)特征

Overvoltage and Feeder Detection for Earth Fault Under High-Resistance Grounding Mode in 10 kV Distribution Networks

10kV配電網(wǎng)經(jīng)高阻接地方式下過(guò)電壓及接地故障選線

Analysis and Prevention of Overvoltage Breakdown in BKD1-500/ 1 140、660 Leakage Protective Device

BKD_1-500/1 140、660中漏電保護(hù)單元出現(xiàn)過(guò)電壓故障的分析及預(yù)防

The Fault Diagnose of Electric Power Transformer Based on Fault Tree Analysis;

基于故障樹(shù)分析法—電力變壓器故障診斷

The Research on Fault Model and Fault Collapsing of Digital Circuit;

數(shù)字電路的故障模型和故障壓縮方法研究

The power supply will not be auto recovered when faults remove.

當(dāng)輸出電壓超過(guò)額定電壓時(shí),電源將保護(hù),故障排除后不能恢復(fù)正常工作。

Troubleshooting of Integrated Circuit Voltage in HQ-450XM Developing System

HQ-450XM洗片機(jī)集成電路電壓故障一例

Fault Analysis and Treatment of Voltage Transformer in 35 kV Substation

35kV變電站電壓互感器故障分析及處理